Quantcast
Channel: Refrigeration-Engineer.com forums
Browsing all 9116 articles
Browse latest View live
↧

Fault on mitso split system

6month old unit The air con is coming up with a Fault flashing 7 times. In the manual it says Problems could be . Refrigerant is insufficient. = Refrigerant is leaking Heat exchanger sensor 1 error =...

View Article


Woolworth's Buy Austral Refrigeration

Today Woolworth's has purchased Austral Refrigeration and is to be known as Retail FM (Facilities Management) What I think is a sad day for the industry to have a company who already dictates terms...

View Article


Daikin BRC1D52 Controller

Hi I want to move my Daikin BRC1D52 Controllers to a more central location, does anyone know how far the maximum cable length i can use is? Thanks

View Article

Transfrig Truck units

Howzit all, I'm having trouble with finding manuals and wiring diagrams for Transfrig Unit model no: KV760 TE380/24 Would anyone be able to assist me?? Thanx

View Article

lp switch and hp switch

hi, im new to this industry and would like to find out on what pressure a lp switch breaks the contact and at what pressure does a hp switch make or brake on airdale air conditioning units. thx a lot

View Article


Copper Pipe - Split Sytem. Sizes?

Gday. Im in australia if that makes any differance. I have a 2 Samsung 2.5kw (1hp) split systems to install. The Samsungs are suggesting for me to use 3/8", 1/4" twin copper tube. I already have a 20...

View Article

VRVII index related questions

Let’s take a REYQ28M with a nominal cooling capacity of 78.5 kW (Indoor temp. : 27°CDB, 19.0°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5m according to catalogue) We connect indoor...

View Article

L G Art cool gallery A12AW1

Hi all i have a fault with art cool gallery. unit was running in heating then fan stopped, louvres stayed open as does the fascia. operation (green) light constantly flashing with no 3 second pause had...

View Article


how inverters control condensation pressure ?

Hello How an inverter split air conditioner is controlling the CP with its discharge, pipe, and ambient temperature sensors ?

View Article


Hill Phoenix Wallmart Freezer blowing fuse in MR4 Temp Controller

I have a Hill Phoenix Walmart commercial freezer. The Johnson Controls MR4 Temperature/Defrost Controller stopped lighting up so I replaced the unit with a direct replacement unit of the same make and...

View Article

Banked hours

Hello there, Does anyone have any experience with banked hours?. Kind of like being paid to sit around when it is quite, like in winter, and then working when it is busy, like in the summer, without...

View Article

fan coil unit refurbishment

Hi all I have recently been asked to carry out some refurbishments to 60 fan coil units with one of my customers and this is not my area of expertise. They are 4 pipe units with 3 speed fan. we are...

View Article

samsung sr-s2026cvw

hi im new here and my freezer has started to play up again 2 years ago it had both boards replaced and now it is turning its self off after about 7 hours if you turn it off at the plug and turn it back...

View Article


beko frost free fridge freezer not working (not cold enough) - help

Have had the fridge freezer over 2 years and moved recently. Its in an internal garage. Its working but not cooling enough. The fan doesn't work no matter what the thermostat is set to. Have slaved a...

View Article

Mixed Indoor - Outdoor Split Units, Daikin & ACSON

Hi there, Does anyone here know if is is possible to use ACSON branded outdoor units for similar capacity Daikin indoor units? These are for single splits. The only problem I can think of is with...

View Article


Rittal SK3303100 FAULT

Hi all Anyone out there familiar with Rittal enclosure units with basic controller?. I have a unit that is in fault and will not run the compressor. The unit is a Rittal SK3303.100 enclosure cooling...

View Article

Image may be NSFW.
Clik here to view.

Miele KFN12924SD 3yrs old - is this 'rust' to be expected?

Hi - Miele KFN12924SD fridge freezer has just failed, after 3 years of careful use. First the fridge part lost all cooling. The freezer was OK for a few days after, but now can only get just below...

View Article


compound systems help please

hi there every one im studying compound systems i think ive got the just of it i can see how they work but the bit im stuck that is ....... when refrigerant is coming back from evaporator suction line...

View Article

running cost of refer box

was asked how mutch it cost to run a 40 foot by 8 foot freezer container aprox per week auy idears

View Article

When it went bang it made me jump!

OK Guys, are you sitting comfortably? I got asked by a good customer to attend his site last week, as his local controls specialist (knows his electronics). Could not identify why at various run times,...

View Article
Browsing all 9116 articles