Quantcast
Channel: Refrigeration-Engineer.com forums
Browsing all 9116 articles
Browse latest View live
↧

Can someone answer me this please?

Why on earth are the three pipe ports on the suction side of a reversing valve so close together and the copper tubes not extended to a greater length off the body of the valve so to reduce the chance...

View Article


Alarm-list to GEA GCW750

Hi, does anyone have a full alarm-list to geaGCW750 with a siemens controll?

View Article


BTU/H to KWH Conversion

Does anyone know of a good calculation for BTUH to KWH? I have found some calcs that say .29 KWH per MBTU. NOt sure how accurate this is. A good calc will help me figure enrgy savings when I am asking...

View Article

Image may be NSFW.
Clik here to view.

Anybody has specs or manual of 2006, Thermocold (made in Italy) Chiller...

Hi, I need official specs or manual of the chiller in order to file a request to replace it as a part of a big project we are doing.. Anybody has it? Attached is chiller plaque/ticket thermocold.jpg...

View Article

Samsng error 458

Hello, My MH026FWEA display shows error E559 (outdoos error). My outdoor unit MH060FXEA3A display shows error E458. I think this error is about "outdoor unit fan error". I checked and the fan is...

View Article


Pre Lube on Carrier 30GX

Hello everyone, I don't know if someone out there can help but I have a Carrier 30GX chiller which will not prelube. I believe the oil pump is supposed to start before everything else fires up. This is...

View Article

fujitsu asy9lsacw/aoy12lsac problems

Hi all, I am new to the forum and am after some advice. My uncle has the above split room air conditioner, and after calling out 3 local "fujitsu experts" none of which could resolve the problem, we...

View Article

Refrigerant Leak Detector

Hi fellow members. I am in the market for a new Refrigerant Leak Detector and wondered if anyone could suggest the best on the market at this time for: R22, R407c, R410a etc....... I look forward to...

View Article


Need help with HOT fridge

Firs off all let me say Hello every one im new to this site and glad I found it. Im an electrician and starting to play around with air cons at our company because we have comebacks if we use...

View Article


meteorogical data (DB temp, WB temp etc...)

Hi all, i did not know in with subforum write this question so i post it here :) I need to get meteorological data from past 30 yrs, or the best would be to get typical meteorological year for...

View Article

Is it ok to use timer plug on inverter split outdoor unit

Hi all. Have 4 LG indoor wall mounts connected to outdoor unit. Sick of having to reset the timers each day would it be possible to fit the outdoor a timer plug? Or will this have a detrimental affect...

View Article

Looking for someone to commission my split A/C in London, UK

Have a Mitsubishi Heavy Industries 2.5kw split inverter that I would like someone qualified to commission. Can someone point me in the right direction here? Much appreciated

View Article

Image may be NSFW.
Clik here to view.

Safe to splice evaporator motor wire?

I have a six-year old Hoover HNMF 2805A-80 frost-free fridge freezer. I recently noticed that the freezer was not freezing food properly, although it remains reasonably cold. The fridge portion appears...

View Article


lennox rooftop unit

I,ve got a lennox rooftop heatpump unit with a kp17 comfort controller ,the controller is showing Pb com fault (communication error),the interconnecting wirings ok as i,ve connected the controller...

View Article

Geneglace F250 R1.ABF flake ice head.

Would anyone have service manual for this machine. Geneglace web site has limited access. I have one that is not breaking off ice and need info on salt to water mix. magoo

View Article


field peice

What would be the most accurate & rugged digital manifold to get? Any other then Tesco(570), Sman3, Thanks wrench

View Article

Wimia WSH-244NBE spares

Has anyone any ideas on where to get spares, I need 2 sensors and a fan motor for the evaporator, Its running on R410

View Article


other forums

just joined another hvac forum too see what others are upto, searched forum list and selected a few posts- all fookin golf clubs,ugg boots- also they only had a few members on line, within 5 minutes...

View Article

Hoshizaki Ice Maker

Hi all, just wondering if anyone has a rough idea of the times it takes for a Hoshizaki IM240DME-23 ice maker to drop ice per cycle? Been to the job a couple of times and bin virtually always full but...

View Article

Make a Flush Unit

Hi, the thing is normally we cleand evaporators and piping systems, due the fact the compressor burn down. Usally we use standart thinner, compresed air. We convert an a non-refilable bottle of...

View Article