carrier 30gx

hi friends is there away to turn off 1 circuit on control panel to test run 1 circuit for a while.thankyou

View Article


blast freezer

i want to build a small blast freezer. i am wondering if you could help me to work out the system size. my blast freezer size is 2.5m x 1.2m x 2.1m. thank you. note: in each cycle i want to freeze some...

View Article


my first refer service call

one of the units I found that the capacitor is bad but I can't identify the capacitor because it's all worn off. How would I go about identifying which capacitor I should use. It looks like I have a...

View Article

New evaporator on chest freezer

Hi! I have made a new evaporator for a little 12v chest freezer, the original one have a leak. The evaporator was made of 1/4 cooper tube. I used dancap to estimate the length of the cap tube, the goal...

View Article

Sabroe smc 112s

Hi everyone, does anyone have a service manual for a sabroe smc112s that gives tightening torques etc for a top end overhaul? Email is waynegrey@btinternet.com as as much info as possible would be...

View Article


Freezer room containers

Hi All I want some help regarding freezer containers My company supplied to a client in a hot and humid zone-ambient 34/38 ºC and RH 75%, supplied to us by a foregin company: - 1 x 20 feet polyurethane...

View Article

Daikin fxyh63hjv1 (heat pump) manual

Hi it's my first post. I have problem withe vrv system, 4 from 5 unit inside work fine, but 1 not cooling and not heating. Now I know the EEV is broken , but I can't found on daikin site manual white...

View Article

Effect on screw compressor life

would the learned Forum Members advise this new guy as to what would be the effect on screw compressor life if Delta P of Evaporator is less than 5psi,GPM flowing into Evaporator is less than the Rated...

View Article


aspera compressor failure.

Has anyone had a new compressor fail due to windings down to earth 10 minutes after start up.if so what did you find as the cause.just happened to me for the first time.the old compressor failed with...

View Article


City Multi PURY-P250YMF-C doesn't work properly

Is it possible the poor performance on heating to be due to addresses assigned to the components of the system? The addresses are assigned as follows: OC:75 BC:69 IC: 37, 38, 39, 40, 41, 42.

View Article

Refrigerated Transportation & warehousing

Need a complete solution of refrigerated transportation & warehousing. Hanson Logistics> Refrigerated trucking

View Article

panasonic U-4LA1E5

Hi guys I had four wallmount units off the above outdoor unit with one wired controller. The wallmounts have now been fitted in seperate offices with there own controllers does anyone know if i need to...

View Article

Carrier vector wall trip

Hi does anyone know the recommened 3phase wall amp trip for vector 1800

View Article


Choosing hot water supplied absorption chiller to gas engine

Hello I am in my final year in University and I'm writing my thesis about tri-generation power supply. One of my task is to choose an absorption chiller to a gas engine. The IC engine is a Wärtsilä...

View Article

cold outside temerature=cooler down?

does this make sense? if the ambient temp is 14 degrees F, could this cause higher cooler temp? What should I look for? any suggestions would be greatly appreciated.

View Article


York Chiller programme failure - YAEP

Hi, I have the following problem with the microprocessor board. Kindly advise if anybody has expertize about the york systems. The unit YAEP is not functioning as microprocessor board is found faulty...

View Article

Why isn't alcohol used as a refrigerant?

Is there a reason why alcohol (or a mixture of alcohol and water) isn't used as a refrigerant?

View Article


Can I increase the freezing performance with any modifications?

Hello! Looking for info for my scenario: Background: I go salmon and halibut fishing on a 7 day camping trip. I take a 10CUF chest freezer and a generator. In 7 days I freeze 400lbs of fresh fish with...

View Article

Image may be NSFW.
Clik here to view.

City Multi heating issues

I'm working on a city multi PURY-P300YGM-A. Its cooling fine but not heating at all. When I began work on the unit I noticed a few things. Firstly the unit seemed to be grossly overcharged. Additional...

View Article

Anyone able to point me in the right direction?

Hi guys, Not quite sure where to post this but here seemed the best place. I did my apprenticeship about 4/5 years back but shortly after had a change of career direction (so I thought) and returned to...

View Article