John0246

Hey guys, had a look at a walk in freezer. The system is on R404a. Evaporator iced up due to defective thermostat, the liquid line drier was also blocked as I had a low suction pressure. Replaced the...

View Article


Suggestions about topics to Phd study in the field of refrigeration

Hi guys I desire to do my Phd in refrigeration branch. What are new trends in refrigeration? What topics could you suggest to study during Phd? Thanks in advance.

View Article


Daikin Multisplit 4MXS80E high current

Daikin inverter 4mxs80E with 2 x 2,5KW innside units (4mxs80E2V3B, FTXS25G2V1B, FTXS25CVMB8) Problem : always high amp draw (approx.18 amps), compressor the same frequency in forced mode as when 1 or 2...

View Article

daikin ftx25 indoor has vibration start and stop blower

hi...i have a daikin aircondition in my house and after 5 years ....now the blower on indoor unit has vibration and sound on full speed...other speed doesnt work start and stop only..the voltage on...

View Article

beer cellar

hi guys, i have a customer that needs new cellar cooling but wants it to work over 35c ,because of the few hot days we have here in the uk :D. Anyone know of anyone other than the usual main suppliers...

View Article


Hrp hydrocarbon course tomorrow

Got the hydrocarbon course tomorrow... Thought I'd just say to all them guys on these courses... When the trainer says "any questions" ask something relevant... Not..."I was on this job once and...."...

View Article

testing S1 voltage at condensor then it went bang

Mitsubishi IND slim Split system with 2 indoor cassettes. Put my probes across S1 and the earth next to it from the 230v supply. I was under the understanding that S1 was 208v-240v so was stunned when...

View Article

Found a small stash of R12 - What to do with it?

I was recently contacted by a friend who had been clearing out a shed and found some refrigerant cylinders. They contacted me and I went to see what they had found. It turned out to be four 13kgs...

View Article


cross-charge expansion valve

Hello i have stumbled upen the term cross-charge expansion valve, could someone explain this to me? regards

View Article


Daikin 4PW71247 setback temperature

Good afternoon All I need your expertise to answer a question I have: is it possible to reduce the setback temperature on a controller Daikin 4PW71247 lower than 33°C? :) Can anybody please let Me...

View Article

sb200 thermoking code 36 and 84

i am having issues with 2 units failing after a hour or 2 of run time on electric. pretrip and runs fine on diesel... pretrips and passes on electric-- but as soon as we leave the system fails and...

View Article

Overhaul a Old R12 Arneg Server over advice please

I have a customer who has a 2.5 mtr wide Arneg Serve Over. It was on R12, I knew this time would come ... The Evap coil has started to spring leaks. The engineer brazed them and re gassed with FX56. In...

View Article

seeking advice regarding an evaporator coil change out..

Good day to all, I am a newbie to this site but really appreciate what I have read in the forums you guys are really great for helping everyone out. which brings me to my dilemma. I have a 3.5 ton heat...

View Article


hello folks

hi to all from greek island kefallina have my own small company about 8 years now and mostly i work with daikin VRV found some very helpful answer in your site keep doing the good work :)

View Article

Evap size and EER

Here is my thinking. We typically assume about 400 CFM per cooling ton across the evaporator. But let's say we increase the evaporator size and reduce the blower to 300CFM. The air discharge temp will...

View Article


Combined chiller efficiency calculation

Hi, we would like to know how to calculate efficiency of a combined system of water cooled chiller and absorption chiller. Please provide advice and reference. Thanks

View Article

Lutron Anemometer & Center Leak Detector

Does anyone have any experience of these two pieces of equipment? When considering a Hot Wire Anemometer recently, I was faced with the choice of $1200 for a Testo 725 (with non-replaceable probe),...

View Article


Compressor shaking after air conditioner shutting down

hi i received an old LG heatpump split ac unit that had leakage because of cracked capillary tube i cut 1 cm of the capillary then i weld it made vacuum for 30 minutes then charged it by weight and it...

View Article

Savawatt control

Anyone have any information on the savawatt controls, ie wiring diagram? I have just done a pot change on a walkin freezer, and what a nightmare its been with leaks to say the least. But the old pot...

View Article

Thermoking container MP3000

Hi, my name is Alex velazquez from Cancun Mexico We had a MP3000 that doesnt work nothing, in the display show "err", voltaje is OK, in the maintenance information said that the problem could be the...

View Article